Search
  
Categories
Manufacturers
Top » Catalog » Pitot Static Tester » Series 62xx » » Model 6250

Model 6250: Automated Pitot Static Tester (for light jets)

   
Specifications
Features
   

Static Output

Pressure function

  • range: 0.1 to 32 inHg
  • resolution: 0.001 inHg
  • accuracy: ?0.003 inHg
  • units: inHG, mbar, psi, mmHG, kpa

Pressure Rate

  • range: 0 to 30inHg/min
  • resolution: 0.001inHg/min
  • accuracy: ?1% of rate
  • units: pressure-units/min

Altitude function

  • range: -2000 ft. to 50,000 ft.
  • resolution: 1 foot
  • accuracy: ? 3 ft. @ 0 ft.
  • ? 4 ft. @ 10,000 ft.
  • ? 6 ft. @ 20,000 ft.
  • ? 9 ft. @ 35,000 ft.
  • ? 18 ft. @ 50,000 ft.
  • units: feet, meters

Altitude Rate function

  • range: 0 ft/min to ?10,000 ft/min
  • resolution: 1 ft/min
  • accuracy: ?1% of rate of climb
  • units: feet/min, meters/sec

Pitot Output

Pressure function

  • range: 0.1 to 15 inHg (differential)
  • resolution: 0.001 inHg
  • accuracy: ?0.003 inHg
  • Pt units: inHg, mbar, psi, mmHg, kpa, EPR
  • Qc units: inHg, mbar, psi, mmHg, kpa

Pressure rate

  • range: 0 t0 30 inHg/min
  • resolution: 0.001 inHg
  • accuracy: ?1% of rate
  • units: pressure-units/min (EPR in inHg/min)

Airspeed function

  • range: 0 to 500 knots
  • resolution: 0.1 knots
  • accuracy: ? 1.0 knots @ 20 knots
  • ? 0.3 knots @ 50 knots
  • ? 0.2 knots @ 100 knots
  • ? 0.1 knots @ 200 knots
  • ? 0.04 knots @ 500 knots
  • units: knots, Mach, km/hr, mph

Airspeed Rate

  • range: 0 to 500 knots/min
  • resolution: 0.1 knots/min (0.01 km/hr/sec)
  • accuracy: ?2% of rate
  • units: knots/min, km/hr/sec, mph/min

Mach function

  • range: 0.0 to 1.0 Mach
  • resolution: 0.001 Mach
  • accuracy: ?0.001 above 0.2 Mach

Power requirement

  • 90-260 VAC, 47-440 Hz ;
  • 100 VA, 200VA with heater option
  • Optional internal battery for 8 hours of operation

External Interface

  • RS232, RS232toUSB converter
  • Encoder optional

Dimensions & weights

  • Main unit: 22” x 14” x 9” / 28 lbs
  • Remote unit: 6” x 6” x 1” / 1 lb.

Environmental specs

  • Operating temp. standard: 0?C to 50?C
  • Operating extened: -30?C to 50?C
  • Storage temp. -30?C to 75?C
  • Humidity: 5 to 100%

RVSM & Automated operation at an affordable price!
Simply enter the target set-points for altitude and airspeed and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ? 1 foot and ? 0.1 knot. The tester’s low price makes it very affordable

Calibration period: 1 year

Programmable limits
User-programmable limits for altitude, airspeed, Mach and VSI provide protection to the aircraft.

Negative-airspeed protection
An internal differential-pressure relief valve provides protection against negative airspeed.

Internal Battery (Optional)
The internal battery allows for 8 hours of continuous operation. Re-charge time is only 8 hours.

Low-temperature operation (optional)
With optional internal heaters, the unit can be operated down to -40?C

Jog and Hold features
Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value.

Ground feature
Brings Pitot and Static outputs to ambient “ground” pressure after completing a test. Ambient pressure is constantly monitored.

Profiles feature
A profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 15 profiles can be stored in the unit.

Leak checks
Pitot and Static leak-checks can be performed either independently or simultaneously. Three leak-timers can be programmed to perform timed leaks between 1 to 20 minutes. The display of ?instant? leak rates provides immediate feedback to the user.

Pressure & Vacuum source
Built-in diaphragm pumps provide the pressure and vacuum source for the unit.

Remote unit
The Remote unit is the operator interface for the tester. It features a sunlight-readable 5.8” color display, a back-lit keypad and a touch-screen (which can be disabled). All operations are performed from a single screen which displays all pertinent parameters.

Manual Vent
On loss of power, the unit maintains pressure (except for leaks). The unit can be manually vented to “Ground” at a controlled rate using precision metering valves.

Applications

  • Leak-checks and accuracy-checks on light jets, helicopters and UAV’s
  • Leak-checks and accuracy-checks on small-volume RVSM aircraft
  • Ideal for line-maintenance by commercial airlines

 

 
Downloads:
 
Datasheet
Manual

.
.
This product was added to our catalog on Monday 02 February, 2015.
.
.