Static Port
Accuracy :
- 0.008 inHg
- 8 ft. @ 0 ft
- 24 ft. @ 35,000 ft.
- 48 ft. @ 50,000 ft.
Range : -2000 to 60,000 ft.
Resolution : 1 foot
Climb : 0 to 10,000 ft/min
Leak Resolution : 1 ft/min
Pitot Port
Accuracy : 0.008 inHg
2.0 knots @ 50 knots
1.0 knots @ 100 knots
0.5 knots @ 200 knots
0.2 knots @ 500 knots
Range : 0 to 500 knots
Resolution : 0.1 knot
Leak Resolution : 0.1 knot/min
Calibration Interval: 1 year
Power requirement
90-260 VAC, 47-440 Hz, 50VA
Dimensions & weight
18? x 12? x 7? / 18 lbs
Environmental specs:
Operating temp. 0o to 50oC
Storage temp. -40o to 75oC
Humidity: 5 to 95% non-condensing
|
- Static output can be displayed in Feet, Meters, inHg or
mbar
- Pitot output can be displayed in knots, kmph, inHg or
mbar.
- Protection against over-range of altitude (high and low)
- Protection against over-range of airspeed (high and low)
- Protection against negative airspeed (even during powerloss)
- Protection against excessive leak rates
- Solid state transducers are not damaged by pressure surges
- Precision Metering valves allow very fine control of
altitude, VSI and airspeed
- Pressure and Vacuum pumps are integral to the unit so no
manual pumping is required
- High capacity vacuum and pressure pumps are capable of
overcoming large leaks on
any aircraft.
- Leak checks on Pitot and Static systems are done
simultaneously
- During Leak Check, actual altitude, VSI and airspeed are
constantly displayed
- Actual values and Accumulated leaks of altitude and
airspeed are displayed for
1, 3 and 5 minute periods
- Cross-bleed and Vent valves allows easy venting to
?Ground?
- Unit can be operated on aircraft power (110 VAC/400 Hz)
- No warm-up time
- No Maintenance required other than yearly calibration
- Extremely simple two-point calibration done in inHg
Specifications subject to change without notice
|