
-
Fast and compact measuring instrument with a wide input
range from 200 mV full scale to 800 V full scale without the need for
additional probes or attenuators
-
High bandwidth of 50 MHz to be able to analyze fast
signals accurately
-
No short circuit to ground possible, due to the
differential input. This means extra protection for your PC
-
The two measuring points can be far apart, making it
easy to measure in large installations
-
Fast streaming, up to 10 million samples per second
continuously for fast and long measurements
-
Amplitude accuracy of 0.3% full scale. Most
oscilloscopes have an accuracy of 2 - 3 %
-
No external power supply required. Power is gotten from
a USB port
-
Very versatile Multi Channel software with an
oscilloscope, spectrum analyzer, Y-t recorder and voltmeter with many signal
analysis functions
-
Exporting of measured data to various common data
formats, making it possible to create your own reports
The Handyprobe HP3 is equipped with a differential
input with a maximum input range of 800 Volt DC (566
Volt RMS). Because of the differential input, it is
not possible to create a short circuit to ground
through the oscilloscope. The high input range makes
it possible to use the Handyprobe HP3 without
additional attenuators. See the classroom section
for information about differential measuring.
The advanced driver technology makes it possible to
measure a continuous stream of data from the
Handyprobe HP3 to the computer, at a maximum rate of
10 MSamples/s. The maximum measuring time is only
limited by the available space on the hard drive.
The high sampling rate makes it possible to capture
short events with high accuracy. It is also possible
to monitor e.g. the line power for a very long time
and afterwards view and analyze each cycle of the
signal thoroughly.
The input of the Handyprobe HP3 is differential,
which means that both sides of the input have a high
impedance. There is no connection to ground as in
conventional oscilloscopes which are used with coax
cables and standard probes.
The special low noise Measure lead TP-C812A is
developed for the Handyprobe HP3. It is very
insensitive to external interfering signals. The two
ends can be placed up to two meters apart, while
picking up very little interference. With a
conventional oscilloscope with standard probes this
is not possible. The maximum distance between the
positive side and ground of a standard probe is
usually limited to approximately 20 cm. The Measure
lead TP-C812A for the Handyprobe HP3 does not have
this limitation. Measuring between two distant
points is now no problem anymore. The Measure lead
TP-C812A uses a heat resistant silicone isolation
and shrouded banana plugs.
- Hard carry case
- Low noise, heat resistant differential test lead with 4 mm banana jacks
and colored clips
- 2 test probes with 4 mm banana socket
- 2 crocodile clips with 4 mm banana socket
- Wrist strap
|
|
|